Capacitive field change detector with VDS Approval
EMC20/1
Capacitive field change detector with VDS Approval G120020 of security class C.
Universal capacitive field change detector for monitoring individual objects, such as sculptures, pictures, steel cabinets, medical depots, windows and much more. Use as a single detector for one sensor or in RS485 bus with multiple EMC20 detectors.
The EMC20/1 is equipped with the latest processor generation. This has improved the measurement process and reduced the response time to (8ms).
Several devices can be networked via RS485, also with EMC20/8. A CAN interface is available for additional devices. The networked devices synchronize with each other (the EMC20 with the lowest address takes over the synchronization). The synchronization prevents that the fields of the sensor electrodes, especially from different EMC20/1 or EMC20/8 devices, influence each other.
The range of the monitoring field can be set object-related with hardware and/or software. The trigger criteria for the alarms can be set continuously by software. A distinction is made between alarm, pre-alarm, sabotage – all freely configurable. The device has a very stable oscillator frequency – this is very important for the triggering criteria.
Capacitive field change detectors generally react to changes in ambient temperature. The EMC20/1 is the first capacitive detector to pass the Environmental Class II test at the VDS.
For comparison:
- Environmental class I: +5° C to +40° C
- Environmental class II: -10° C to +55° C
Technical information
Power Supply | 12V DC or 24V DC, Range 9 - 30 VDC | ||||||||
---|---|---|---|---|---|---|---|---|---|
Current comsumption | 85mA ( 12VDC ) | ||||||||
Load capacitance | Selectable: 1nF, 5nF or 22nF | ||||||||
Interfaces | RS 485 , CAN, USB RS 485 , CAN, USB | ||||||||
Inputs | Armed/disarmed; ext. cover contact monitoring | ||||||||
Relay outputs | Switching power max. 10W | ||||||||
<br /> | Switching current max. 0,5A | ||||||||
<br /> | Switching voltage 200V DC or peak AC max. | ||||||||
<br /> | (Exceeding one of the values destroys the reed relay) | ||||||||
Acoustic | Buzzer | ||||||||
Tableau output | 500mA max. current, 60 V DC or 60V AC peak max. | ||||||||
Housing, 2-shell | Bottom shell V4A , top shell steel plate gray powder coated, screwed( T10x50). | ||||||||
Weight | 850 g | ||||||||
Dimensions | 190 x 80 x 40 mm | ||||||||
Protection class | IP54 | ||||||||
Connection technology | Plug-in screw terminals max. 1,31mm² LiYCY, | ||||||||
<br /> | Sensor electrode: SMB connector for coax cable RG179 max. 10m for sheet metal electrodes. | ||||||||
<br /> | Strain relief ( T10x50 ) for all cables | ||||||||
<br /> | Optional cable openings for your application | ||||||||
Article/Order number | EMC2001 | ||||||||
EMC20/1
Universal, capacitive field change detector for monitoring individual objects. Use as single detector for one sensor.
EMC20/8
Universal, capacitive field change detector for monitoring objects. For 8 sensors
EMC20/1 for inductive monitoring
Together with a cable transformer and a grid structure, the EMC becomes an inductive monitor.